CP 0020
Overview
To reduce the risk of serious injury or death
to yourself or others, read the Safety
instructions section found on the previous
pages of this manual before operating the
machine.
Design and function
CP centrifugal pump is intended for pumping
relatively clean liquids such as water and coolants.
It is not recommended to pump any liquid with a
temperature above 212°F (100°C). Do not pump
abrasive liquids. No other use is permitted. CP 0020
is adapted to meet different demands in respect of
flow and pressure head, see diagram below.
CP 0020 is submersible, which means that it can
work fully submersed in the pumped medium. The
impeller of CP 0020 is in sand-cast gun metal, driven
by an air motor. The compressed air flows through
an air-filter which stops any foreign matter from
entering the pump. The integrated oiler provides
continuous lubrication.
The diagram is valid at 6 bar (87 psi) and when
pumping from base plate level. Use of a suction hose
will decrease possible head.
H: Head feet (m)
Q: Flow imp gal/min (l/s)
NOTICE
The capacity of the pump will change
and the chart above will not be accurate if a lower
air pressure than the recommended is used, or if the
pumped liquid has a different viscosity than water.
9800 1056 90a | Original instructions
Safety and operating instructions
Main parts
Mechanical seal
A.
Air filter
B.
C.
Motor
D.
Filter screen
Liquid intake
E.
Discharge outlet
F.
Impeller
G.
H.
Governor
I.
Valve
Air inlet
J.
Venting hole
K.