REMOTE CONTROL LED INDICATORS AND
ALERTS
Figure 5. Remote Control LED Indicators and Alerts
15 Power LED Indicator
16 MILWAUKEE M18 Battery
Indicator
17 Weight Overcapacity
Indicator
Power LED Indicator
Remote Control ON and connected to the hoist
Indicator is solid green
Low Battery in Remote Control (approx. 4 hours of runtime)
Indicator is slowly flashing green
Pairing/Linking Mode
Indicator is intermediately flashing green
Pairing/Linking unsuccessful
Indicator is quickly flashing green for 1 minute
Remote Control is OFF
Indicator is off
Hoist enters Sleep Mode
Remote Control turns OFF
Indicator is OFF
MILWAUKEE M18 Battery Indicator
Low Battery (12.0 Ah battery at 25% SOC)
Indicator is slowly flashing red
Dead battery
Indicator is solid red
Hoist does not operate until battery is replaced
Battery Out-of-Temperature
Indicator is solid red
Hoist does not operate until battery is within normal
operating temperature
Weight Overcapacity Indicator
Directional Button UP (4) is pressed while the hoist load is
over weight capacity
Hoist stops, load cannot be lifted
Indicator is solid red
Hoist buzzer sounds
BatteryStar
TM
18 Operator Indicator
19 Inspection Indicator
20 Pairing/Linking LED
Indicator
Operator Indicator
Hoist is above or below the safe operating temperature
Indicator is solid red
Hoist does not operate until operating temperature or
conditions with product specifications are reached
Hoist electronics error
Indicator is solid red
Hoist does not operate
Inspection Indicator
If hoist inspection is due based on 365 day interval after
initial ONE-KEY
TM
Indicator is solid red
Hoist does still operate
Hoist inspection is due within 30 days
Indicator is slowly flashing red
After inspection
Indicator must be cleared via ONE-KEY
connected to the hoist
NOTE Inspection indicator will illuminate 365 days
after initial ONE-KEY
that the yearly inspection is due. Yearly inspection
is based on normal use. For normal operation
requirements, see "Inspection", page 11. If hoist is
used in heavy or severe applications then inspections
may need to be performed more frequently which may
be configured via the ONE-KEY
Pairing/Linking LED Indicator (located behind battery door)
Pairing/Linking Mode
Indicator is immediately flashing green
Successful Pairing/Linking
Indicator is solid green for 5 seconds
Pairing/Linking Error
Indicator is quickly flashing green for 1 minute
Security Lockout Indicator
Hoist is locked via ONE-KEY™
All alert indicators are solid red
Refer to ONE-KEY™ section for instructions on unlocking tool.
ONE-KEY
TM
CHEMICAL BURN HAZARD
This device contains a lithium button/coin cell battery. A new
or used battery can cause severe internal burns and lead to
death in as little as 2 hours if swallowed or enters the body
TO AVOID INJURY:
Always secure the battery cover. If it does not close securely,
stop using the device, remove the batteries, and keep it away
from children. If you think batteries may have been swallowed
or entered the body, seek immediate medical attention.
Internal Coin Cell Battery
An internal coin cell battery is used to facilitate full ONE-KEY
functionality.
10
Configuration
app while
TM
configuration indicating
TM
app.
TM
WARNING
P/N: 192097707YLEM June 2024