3. Checking the sponge filter element of the air filter: A dirty sponge filter element decreases the air
entering the electronic fuel injection unit, which reduces the generator performance.
Using the Generator
Activation
The generator must be activated before using for the first time. Connect the remote controller to the
internet first. Use a USB-C cable to connect to the USB-C connector of the generator and the USB-A
connector of the remote controller. Run the DJI Agras app on the remote controller and select Device
Management > Charging Device to activate the generator.
Starting the Generator
1. DO NOT connect to any electric devices before starting the generator.
2. Make sure the engine has been filled with engine oil and the fuel tank with no less than 1L fuel.
3. Turn the fuel valve to the ON position.
4. Connect the charging cable to an Intelligent Flight Battery that is powered off. Press and then press
and hold the power button on the battery to power on the battery.
5. Move the engine switch to the START position and hold for at least 3 seconds and then release. The
engine switch will return to the ON position and the generator will start automatically.
6. The generator starts to charge the battery. Each of the four LEDs of the battery blinks successively
during charging. Remove the battery when the four LEDs turn solid or off and connect another
battery to charge.
• The battery must be powered off before connecting it to the generator.
• The generator automatically attempts to start a maximum of three times every time the
engine switch is moved to the START position with an interval of five seconds between each
start attempt. If the generator fails to start after three automatic attempts or stops right
after starting, connect it to the remote controller to see more information regarding the
malfunction.
• If there are any working electric devices connected to the AC outlet while charging the battery,
the charging capacity for the battery will decrease accordingly and the charging time will be
extended.
Stopping the Generator
1. Turn off all connected electric devices.
2. Move the engine switch to the OFF position and the generator will stop running.
3. Disconnect all connected electric devices.
4. Turn the fuel valve to the OFF position.
Storage and Maintenance
Storage
Follow the steps below for storage if the generator will not be used for more than 30 days.
1. Before storage, start the generator and let it run for five to ten minutes to warm up. Next, stop the
generator to drain the engine oil.
9