2. Take down the engine oil drain hose, open the cap by rotating it counterclockwise, and drain all the
engine oil.
3. Install the engine oil drain hose back in place and rotate the cap clockwise to tighten it.
4. Extract the fuel out from the fuel tank to a dedicated container and drain the fuel in the high-
pressure oil pipe and the fuel pump to avoid gum formation.
5. Turn the fuel valve to the OFF position to cut off fuel supply.
6. Place the generator in a cool, dry, and clean place.
• To avoid scalding, DO NOT touch hot engine oil.
Draining Oil in the High-Pressure Oil Pipe and the Fuel Pump
1. Connect the Intelligent Flight Battery.
2. Turn the fuel valve to the OFF position. Place
a container under the high-pressure oil pipe.
Remove the bolt that secures the high-pressure
oil pipe. Press with the thumb and index finger
to open the latch between the high-pressure oil
pipe and the fuel pump to disconnect them. Place
the high-pressure oil pipe down to drain the fuel
inside.
3. Connect a hose to the outlet on the fuel pump.
Move the engine switch to the START position
and release immediately. The fuel inside the fuel
pump flows to the container through the hose.
4. Move the engine switch to the OFF position and
install the high-pressure oil pipe back in place
after draining all the fuel.
Transportation
The generator especially its exhaust system can become very hot during running. To avoid scalding
or fire of flammable materials, if the generator has been running, wait for at least 15 minutes to let
it cool down before moving it into a transportation vehicle. Make sure the generator is stable during
transportation and the fuel valve is in the OFF position to avoid spilling.
Maintenance
Scan the QR code on the fuel tank to view the tutorial videos or refer to the labels and stickers on the
generator for maintenance instructions.
Check and maintain the generator regularly to keep it in good condition.
Maintenance Safety Notices
• Before maintaining, stop the generator, disconnect all the electric devices and batteries, and let the
generator cool down completely.
• Maintain the generator in a clean, dry, and stable place. Make sure the generator cannot move by
accident.
• Read the user guide before operation and make sure you have all the tools and the necessary skills.
• Be extremely careful when using the generator near fuel to decrease the possibility of a fire hazard
or explosion. Use non-flammable solvent to clean the parts. DO NOT use fuel for cleaning. Keep the
parts with fuel away from cigarette butts, sparks, and fire.
10
Fuel Pump
Outlet
High-Pressure
Oil Pipe