SAFETY
•
Means for disconnection from the supply mains, which have a
contact separation in all poles that provide full disconnection
under overvoltage category III conditions, must be incorporated
in the fixed wiring in accordance with the wiring rules.
•
The appliance shall be installed in accordance with national
wiring regulations.
•
The installation and service of this product shall be carried out
by professional personnel, who have been trained and certified
by national training organizations that are accredited to teach
the relevant national competency standards that may be set in
legislation.
•
Mechanical connectors used indoors shall comply with ISO
14903. When mechanical connectors are reused indoors,
sealing parts shall be renewed. When flared joints are reused
indoors, the flare part shall be re-fabricated.
•
Reusable mechanical connectors and flared joints are not
allowed indoors.
•
Disconnect the appliance from its power source during service
and when replacing parts.
!
C A U T I O N
•
Do not use any sprays such as insecticide, lacquer, hair spray or
other flammable gases within approximately 1 meter from the
system.
•
If circuit breaker or fuse is often activated, stop the system
and contact your service contractor.
•
Do not make service or inspections tasks by yourself. This work
must be performed by qualified service person.
•
Do not put any foreign material (sticks, etc...) inside the units.
These units have high speed rotating fans and it is dangerous
when any object touches them.
•
Refrigerant leakage can cause difficulty with breathing due to
insufficient air.
Installation and service engineering must comply with local
•
standards, laws and regulations. The standards (British Standard,
BS4434) may be applicable if local regulations are not available.
•
This air to water heat pump has been designed for standard water
heating for human beings only. Do not use this for other functions
that are not included in the wired controller.
Do not install the unit in the place where the breeze directly
•
catches the animals and plants. It could adversely affect the
animals and plants.
•
Pay attention to the following points when the unit is installed in
hospital or other facilities where there are strong electromagnetic
waves from medical equipment.
- Do not install the unit where the electromagnetic wave is
directly radiated to the electrical box, wiring, wired controller
and adapter.
- At least 3 meters from strong electromagnetic wave radiators,
such as radio equipment.
•
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
This appliance can be used by children aged from 8 years and
•
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
?
N O T E
•
It is recommended to ventilate the room every 3 or 4 hours.
•
The air conditioner may not work properly in the following cases.
- The power supplied by the power transformer is less than or
equal to the electric power of the air conditioner.
- The large power-consuming equipment is too close to the
power supply wiring of the air conditioner,large surge voltage
may be inducted in the power supply wiring of the air
conditioner.
5