If necessary:
6. Continue with inflation to the maximum value of 3.5
bar to correctly position the tyre on the rim. Avoid dis-
tractions during this operation, and continually check
tyre pressure on the air pressure gauge (1, Fig. 40D)
to prevent excessive inflation. Inflating tubeless tyres
requires a higher air flow-rate to allow the beads to
bypass the rim HUMP - see types of rim profiles for
mounting without an air chamber in fig Fig.40E .
7. Check that the beads are correctly inserted in
the rim; otherwise, deflate the tyre, break the
beads as described in the relevant section,
lubricate and turn the tyre on the rim. Repeat
the mounting operation described previously
and check again.
8. Reinsert the internal valve mechanism.
9. Bring the pressure to the operating value by
pressing the inflation button (2, Fig. 40D).
10. Place the cap of the valve.
6.12.c. SPECIAL PROCEDURE (TI VERSION)
Before starting with the operations described below, make sure there is no dirt, dust or
other impurities near the inflation nozzles.
If while inflating the tyre is not positioned correctly on the rim due to excessive space
between the tyre and the rim, a jet of pressurised air can be used with the jaw of the
optional T.I. accessory (quick bead insertion).
Check that both the upper and lower beads and
the rim bead seat have been suitably lubricated
with approved paste for mounting.
1. Make sure that the rim is correctly clamped on
the turntable (Fig. 41).
Artiglio Master J Operator manual
"double HUMP" (H2)
WARNING
2
40D
"HUMP" (H)
40E
41
1
EN
143