ELECTRICAL HOOK-UP
The wheel balancer is set up by the manufacturer
to operate with the power supply available in
the place of installation. The set-up data for
each machine are given on the machine data
plate and on a special label attached to the
power supply connection cable.
WARNING
Any operations for hooking up to the workshop
electrical board must be carried out only by
qualified technicians in compliance with the
regulations in force, under the responsibility
and at the charge of the customer.
The electrical hook-up must be performed
according to:
• Absorbed power specifications indicated on
the machine data plate.
• The distance between the machine and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when
starting up) of the rated voltage specified on
the data plate.
- The user must:
• Connect the machine to its own electrical
connection fitted with a suitable 30-mA current
sensitive circuit breaker.
• Power line fuses in accordance with specifica-
tions in the main wiring diagram of this manual.
• Provide the workshop electric installation with
an efficient grounding circuit.
- Prevent unauthorised use of the machine,
always disconnect the power supply plug
when the machine is not used (switched off)
for extended periods of time.
- If the machine is connected directly to the
power supply by means of the main elec-
trical board and without the use of a plug, a
key operated or padlockable switch must be
installed to restrict machine use exclusively
to qualified personnel.
WARNING
A good grounding connection is essential for
correct operation of the machine. NEVER connect
the machine ground wire to a gas pipe, water
MT 3800 LASER - Operator's manual
pipe, telephone cable or any other unsuitable
object.
COMPRESSED AIR
HOOK-UP
CAUTION
The compressed air hook-up may only be per-
formed if the pneumatic ring nut is supplied
(optional accessory supplied on request).
WARNING
All compressed air hook-ups must be carried
out by qualified personnel only.
- The hook-up to the workshop compressed air
system must ensure a minimum pressure of
8 bar.
- The union for connecting to the compressed
air system is of a universal type and therefore
no special or additional couplings are required.
A pressure-resistant hose with 6mm inner
diameter and 14mm outer diameter must
be fixed to the notched union using the hose
clamp provided with the machine.
SAFETY REGULATIONS
WARNING
Non compliance with the instructions and
danger warnings can cause serious injuries
to the operator or other persons.
Do not operate the machine until you have
read and understood all the danger/warning
notices in this manual.
In order to operate the machine correctly, it is
necessary to be a qualified and authorised oper-
ator, able to be trained and to know the safety
regulations. Operators are expressly forbidden
from using the machine under the influence of
alcohol or drugs capable of affecting physical
and mental capacity.
The following conditions are essential:
- Read and understand the information and
instructions described in this manual.
- Have a thorough knowledge of the features
UK
51