Care Of The Functional Stocking; Legal Information; Trademarks; Technical Data - Ottobock 3F1-1 Instrucciones De Uso

Ocultar thumbs Ver también para 3F1-1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
INFORMATION
Drying may take between 12 and 24 hours. A second functional stocking for changing is recom­
mended.

7.3 Care of the functional stocking

Wipe the silicone coatings on the inside of the functional stocking with a damp cloth every
three days.

8 Legal information

8.1 Liability
The manufacturer will only assume liability if the product is used in accordance with the descrip­
tions and instructions provided in this document. The manufacturer will not assume liability for
damage caused by disregarding the information in this document, particularly due to improper
use or unauthorised modification of the product.
8.2 CE conformity
This product meets the requirements of the European Directive 93/42/EEC for medical devices.
This product has been classified as a class I device according to the classification criteria out­
lined in Annex IX of the directive. The declaration of conformity was therefore created by the man­
ufacturer with sole responsibility according to Annex VII of the directive.

8.3 Trademarks

All product names mentioned in this document are subject without restriction to the respective
applicable trademark laws and are the property of the respective owners.
All brands, trade names or company names may be registered trademarks and are the property of
the respective owners.
Should trademarks used in this document fail to be explicitly identified as such, this does not justi­
fy the conclusion that the denotation in question is free of third-party rights.

9 Technical data

Environmental conditions
Storage and transport in original packaging
Storage and transport without packaging
Operation
General information
Reference number
Service life of the functional cosmesis
Service life of the functional stocking
14
-25 °C/-13 °F to +70 °C/+158 °F
-25 °C/-13 °F to +70 °C/+158 °F
Max. 93% relative humidity, non-condensing
-10 °C/+14 °F to +60 °C/+140 °F
15% to 93% relative humidity, non-condensing
3F1=1 / 3F1=2
2 years
The service life diminishes or increases
depending on the individual level of use. Only
when the instructions for use are observed it is
possible to achieve the maximum service life, in
dependence of the level of use.
6 months
Wear part, subject to natural wear and tear.
The service life diminishes or increases
depending on the individual level of use. Only