Applying Balancing Weights In The Alu1P Or Alu2P Programmes - Corghi CompactLine EM 9250 Manual De Uso

Ocultar thumbs Ver también para CompactLine EM 9250:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

o'clock.
Some slight residual unbalances may remain at the end of the test spin due to the
considerable difference in shape that may be found on rims having the same rated
dimensions. Therefore modify the value and position the previously applied weights
for accurate wheel balancing.
9. APPLYING BALANCING WEIGHTS IN
ALU1P OR ALU2P PROGRAMMES
• Adhesive weights applied with the weight-holder device (if provided) and after chang-
ing the application position from 12 o'clock with the CLIP in the "Adhesive weight
application position" setup menu
1
Select the first side to be balanced.
2
Turn the wheel until the central element of the corresponding position indicator
lights up. Keeping the wheel in position with the clamping brake, a display will
now show the quantity of the weight to be applied in gr/ounces and the other will
display the distance in mm alternatively to the plane identification abbreviation
(A-1 for Inner Plane/A-2 for Outer Plane).
3
Position the adhesive weight inside the cavity of the weight-holder device (Fig.
18,a,b).
4
Remove the adhesive protective film (Fig. 18c).
5
IN THE MACHINE VERSION WITH AUTOMATIC SENSOR move the sensor until
it reaches the indicated position. During this phase, the unbalance value of the
side to be balanced is shown on one display, whereas the numerical value up-
dated according to the sensor position, which becomes zero when the position
for application of the weight is reached, is shown on the other display.
IN THE MACHINE VERSION WITH MANUAL SENSOR with the wheel in a centred
position, the machine indicates the unbalance value on a display, whereas the
other display shows the message "d1" or "d2" alternately to the distance value of
the plane corresponding to the body.
Move the sensor to the position shown on the display in which the message "d1"
or "d2" appears alternately to the distance value (the distance is read on the rule).
6
Turn the end of the measuring arm until the weight adhesive strip is in line with
the rim surface.
7
Press the key (Fig. 18d) to eject the weight and make it stick to the rim.
8
Return the measuring arm to the rest position (Fig.18e).
9
Repeat the operations to apply the second balancing weight.
10 Perform a test wheel spin to check the balancing accuracy.
The rim surface must be perfectly clean to make the weight stick efficiently to the rim. If
necessary, clean the surface using suitable cleansing products.