Checking the operational readiness
of the display unit
Check for operational readiness
Switch on the industrial truck.
The Safety Guard display unit switches on and
is ready for operation after approx. 15 sec-
onds.
Check LED (1) on the display unit.
The LED must flash green.
Checking pairing with a mobile warning
unit
If the driver is carrying a mobile warning unit, it
must be paired with the Safety Guard display
unit. This prevents a warning message from
being triggered.
Pairing is carried out automatically:
LED (2) lights up green:
●
Mobile warning unit is paired and within
range of the display unit.
LED (2) lights up red:
●
Mobile warning unit is paired but not within
range of the display unit.
Checking the operational readiness
sensors
The sensors must be ready for operation be-
fore work operations begin. Check LEDs 1 to
4 (1). LED 4 is optional.
Switch on the industrial truck.
The Safety Guard display unit switches on.
LEDs 1 to 4 light up green for ten seconds.
●
If the sensors are ready for operation, the
●
LEDs go out after ten seconds.
If a sensor is faulty, the corresponding LED
lights up red.
Faulty sensors cannot merely be replaced.
The sensors must be registered with the Linde
Safety Guard system via the configurator.
Contact your service partner for advice
Operating Instructions - 3008011701 EN - 11/2019