Functional test of the Safety Guard
zone radio module
NOTE
The functional test must be completed regard-
less of the industrial truck component configu-
ration. When using the Safety Guard commu-
nication unit, perform the following steps as
well.
The functional test checks the warning zones
that have been set and any responses that
have been set on the industrial truck.
 Switch on the industrial truck.
The display unit switches on.
 Check the operational readiness of the
Safety Guard zone radio module.
The "operating status" LED must flash green.
 Drive the industrial truck to the warning
zone. During this process, the driver moni-
tors the display unit and any responses that
have been set on the industrial truck. A sec-
ond person monitors the Safety Guard zone
radio module.
Fault messages and irregularities on the dis-
play unit or the radio module during the test
are not permitted.
 If necessary, have the warning zones and
the truck settings set up again by the serv-
ice partner.
Operating Instructions - 3008011701 EN - 11/2019
4
Operation
Pre-shift checks
1
2
3
4
LSG_0060
49