by means of a cable (6 fig.6) connected to the main terminal board of the drive section. The
other section-to-section connections are made exactly as described in the previous
example and illustrated in fig. 6.
The electrical hook-up should be carried out following the instructions given in the section
Electric and Pneumatic Hook-Up.
These instructions also apply to corner configurations. The cables for the corner should be
inserted in the supports provided.

ELECTRICAL AND PNEUMATIC HOOK-UP

WARNING
All operations required for the electrical hook-up of the machine must be carried out
exclusively by a qualified electrician.
- The electricity supply must be suitably rated in relation to:
• the machine's electrical power absorption, specified on the machine's dataplate.
• the distance between the machine and the power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10% during start-up) below the rated voltage
specified on the dataplate.
- The user must:
• fit a power plug in compliance with the current regulations on the power supply lead
• connect the machine to its own electrical connection having a specific automatic
differential circuit-breaker, with sensitivity 30 mA
• fit fuses to protect the power supply line, rated as indicated on the general electrical
system diagram enclosed with this manual
• provide a suitable ground system on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when the
machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
panel without the use of a plug, a key-switch or device with padlock fixture must be
provided to restrict use of the machine to authorised personnel only.
NOTE
The machine version equipped with the splicer accessory includes a pressure regulator
set to 6 bar (for standard machine use).
WARNING
An efficient grounding circuit is essential for safe and correct machine operation.
NEVER connect the grounding line to gas or water lines, to telephone wires, or to other
non-suitable objects.