  • MX

Idiomas disponibles

6.
Stop button
-
This stops the wheel for 50 seconds to allow
wheel mounting/demounting or weight ap-
plication.
-
Interrupts the unbalance measuring cycle.
SECONDARY CONTROL
KEYPAD
The secondary control keypad can be used to
quickly modify machine status and consists of
the following five buttons:
1.
enables/disables the Weight Management
suite:
-
Select this button to activate the Less Weight
programme for weight saving consisting of two
balancing modes:
optimised mode for fast vehicle
wheels;
or
optimised mode for slow vehicle
wheels;
press the button again to deactivate the
Weight Management suite.
Wheel balancing is performed using the de-
sired balancing programme. At the end of the
spin, if wheel balancing is considered satisfac-
tory, the position indicators will display the
icons
and two semicircular indicators
for indicating the residual rotation torque
unbalance level (left indicator) and static
rotation torque level (right indicator).
2.
selects the required operator:
-
This button can be used to change operator
quickly.
-
3 operators can be selected (1, 2 or 3) and
named (see the "Customisation" section).
-
When a new operator is selected, the machine
EM9980 - Operator's manual
resets the parameters that were active at the
last recall.
The stored parameters are:
-
Balancing mode; Dynamic, ALU, etc...
-
Wheel dimensions.
-
Last phase of OPT.
-
General machine settings: grams/ounces,
sensitivity x5/x1, etc...
3.
Balancing environment
This function makes it possible to select the
working environment required based on the
type of wheel to be balanced:
- AUTO for vehicle wheels with a central hole
- MOTO for motorcycle wheels
- FLANGE for vehicle wheels without a central
hole
In the FLANGE and MOTO environment, the
automatic clamping system pedal is disabled
as the wheel is centred using the respective
accessories.
Using the wheel balancer in FLANGE mode
remains the same as the AUTO environment, in
the MOTO environment the methods change
as described in the "Motorcycle wheel balanc-
ing" section.
4.
Enables/disables the unbalance display
mode (gx1 or gx5).
-
Select this button to display the unbalance
mass in grams:
to the nearest gram or 1/10 of an
ounce if the unit of measurement has been
set to ounces;
or
to the nearest 5 grams or 1/4 of an
ounce if the unit of measurement has been
set to ounces.
This function is not enabled in the ALU1 and
ALU2 programmes (see the "Shift Planes pro-
gramme" section).
5.
print menu:
-
Select this button to access the print menu
for the programme that is running.
The following is possible in the menu:
UK
53