Lifting Arm Assembly - Nussbaum POWER LIFT HF 4600 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

After setting up the electrical connection to the lift,
the hydraulic system can be filled.
9
9 Operating lever
10 2 x Allen key operating lever
11 Oil filling opening
• Loosen and remove the plastic part of the oper-
ating lever (9) of both Allen screws (10).
• Loosen and remove the unit cover.
• Unscrew the oil filling opening (11).
• Fill hydraulic oil (HLP 32). 9 litres of HLP 32 are re-
quired.
• Raise the lift approx. 1 m by pushing the operat-
ing lever (9). The lift rails can be lifted at different
times!
• Plug in the lifting arm bolts and provide with safety
rings.
• Push the operating lever forwards and raise the lift
to its uppermost end position.
• Push and hold the operating lever for another 60
seconds so air can escape from the system and
the overflow procedure equalises the lift to each
other.
For first commissioning, it is normal to have a differ-
!
ent start up and a large "shaking" in the uppermost
position. Air trapped in the system must be com-
pletely removed first.
• Afterwards lower the lift to its lowest position. Pull
the operating lever (9) and hold it until the lifting
arm is completely lowered.
The oil level should be approx. 30 – 40 mm below
!
the oil fill opening. Do not fill the oil tank up to the
upper edge, as otherwise during lowering the oil
return line can pull oil out of the line and afterwards
result in a very slow lifting at the upper range.
• After commissioning, the sticker (first filling) can be
removed.
76
First filling without sticker.
Required oil volume: 13 litres (HLP 32) for system,
hoses and cylinders.
• After setting up the electrical connection to the
lift, the hydraulic system can be filled.
10
• Loosen and remove the plastic part of the oper-
ating lever (9) of both Allen screws (10).
• Loosen and remove the unit cover.
• Unscrew the oil filling opening (11).
• Fill hydraulic oil (HLP 32). 9 litres HLP 32.
• Raise the lift approx. 1 m by pushing the operating
lever (9).
• The lift rails can be lifted at different times!
11
• Hang in the lifting arms and provide with safety
rings.
• Push the operating lever (9) forwards and raise
the lift to its uppermost end position.
• Fill the tank with hydraulic oil HLP 32. About 4 litres
are still needed.
• Push and hold the operating lever for another
60 seconds so air can escape from the system
and the overflow procedure equalises the lift to
each other.
For first commissioning, it is normal to have a differ-
!
ent start up and a large "shaking" in the uppermost
position. Air trapped in the system must be com-
pletely removed first.
• Afterwards lower the lift to its lowest position. Pull
the operating lever (9) and hold it until the lifting
arm is completely lowered.
The oil level should be approx. 30 – 40 mm below
!
the oil fill opening. Do not fill the oil tank up to the
upper edge, as otherwise during lowering the oil
return line can pull oil out of the line and afterwards
result in a very slow lifting at the upper range.
8.2

Lifting arm assembly

Hang in the standard lifting arm and then place an
acid-free multi-purpose grease into the joint bolts in
each case from above into the hole and then insert
the enclosed locking ring.
OPI-POWER LIFT HF 4600-HYMAX HF 4600-V2.3-DE-EN-FR-ES-IT
The lifting arm bolts must be secured
on both sides as otherwise a reliable
connection is not given between the
lift rails and lifting arm.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hymax hf 4600

Tabla de contenido