600 Diagnostic: Codes
GB
Status Display
9
A
1
Starla manual 2 way swivel interlock motor timed out
Starla manual 2 way swivel. Both switches activated
2
Simultaneously.
3
Starla / Siena power swivel encoder fault. All outputs 'off'
Starla / Siena power swivel centred switch fault. Switch still
4
activated when encoder centred
5
Starla power swivel encoder sequence error.
6
Starla power swivel encoder incorrect sequence in travel
1
Main ECU failure
2
Option PCB failure
3
Intermittent connection between main ECU and option PCB Check connection between boards
1
Con 7 wiring loom short circuit between A&B CCTS
2
Con 9 wiring loom short circuit between A&B CCTS
3
Con 10 wiring loom short circuit between A&B CCTS
4
Con 17 wiring loom short circuit between A&B CCTS
5
Con 18 wiring loom short circuit between A&B CCTS
2
Stairlift handing not specified.
3
Starla / Saxon swivel wiring incorrect.
4
F
F
Main ECU software failure
* If Fault Code identifies switch / wiring fault and testing the circuit proves no fault. ECU failure should be assumed.
Resetting Encoder following a sequence fault
If Resetting the power does not clear an encoder sequence fault, this may be due to the fault occurring during an
inwards travel operation. To reset the fault use the following method:
1.
Switch power 'OFF'.
2.
Set switches 'F' and 'G' on SW7 on options board to the 'OFF' position. (Refer to page 9 for switch location).
3.
Switch power 'ON'
4.
Switch power 'OFF' and reset switches to desired configuration (Refer to page 9 for switch configuration).
5.
Switch power 'ON'.
Accessing Stored Fault Codes
To access this feature:
1.
With carriage switched on
2.
Remove carriage cover to access the main ECU
3.
With status display showing '2', De-latch SW3
4.
If there is a stored fault code, the Status Display (LED 9) will cycle between 'H' and 'h'. The Fault Display LED's
will cycle simultaneously.
Example:
H4-h3
Indicates 'Footrest motor not detected' as the last stored fault. (Equivalent to fault 9,4-A,3).
5.
To clear the stored fault, press and hold SW4 for 4 seconds. The stored fault will be permanently removed.
6.
Re-latch SW3 to return stairlift to normal operation.
NOTE. A stored fault cannot be displayed if the Status Display is indicating '9'.
8
7
6
5
Press and
De-latch
SW3 to
show stored
fault
56
Fault Codes
FAULT
New SL swivel detected (SL encoder) not supported.
SW4
4
Fault Display LED's will
3
Cycle at the same time
2
as the status display
1
ED9
L
Check change over mechanism
Check switches / check wiring
Check encoder / connections/ slot
alignment
Check switch / encoder connections
Check / replace encoder
Refer to instruction below to reprogramme
encoder / Replace encoder
Replace main ECU
Replace option PCB
Check wiring loom con 7
Check wiring loom con 9
Check wiring loom con 10
Check wiring loom con 17
Check wiring loom con 18
Check handing plug fitted correctly
Check chair loom con10
Replace main ECU to the latest version
Replace Main ECU
Status Display will cycle
between 'H' and 'h'
ACTION
SW4
8
4
7
3
2
6
5
1
LED9
Press and hold SW4
for 4 seconds to
permanently
clear
the stored fault