Beha-Amprobe EV-500 Serie Manual De Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 45
Please refer to the manufacturer's recommendation and national standards which are linked to IEC/HD 60364-6
for initial test or IEC/HD 60364-7-722.
Required tests are:
• Visual inspection
• Continuity of protective conductors and protective bonding
• Insulation resistances
• Loop / line impedance
• RCD test
• Function tests (including but not limited to):
- Vehicle state A, B, C, D,
- Error handling (error "E", PE Error (Earth Fault), ...)
- Communication (PWM signal)
- Mechanical locking of plug
- Rotary field/phase sequence
- Other tests
Connection of the EVA-500-D/-CH/-UK/-F Test Adapter to Charging Station
The EV-500 Test Adapter Series can accept the following two connection cables:
• EVC-20 - Type 2 test cable; For charging stations type 2 with panel mount with socket outlet or fixed cable
with vehicle connector (included in scope of supply)
• EVC-13 - Type 1 test cable; For charging stations type 1 with fixed cable and vehicle connector (optional)
Steps for connecting the test adapter to the charging station:
1. Connect corresponding test cable (EVC-20 or EVC-13) to the test adapter EVA-500.
2. Connect above assembly to the charging station to be tested.
Proper test adapter connection to the charging station is shown in Figures 6, 7 and 8.
7-pole male connector
EVA-500-X
Figure 5: Available test cables for the test adapter series
EVC-20
TYPE 2 test cable
6
EVC-13
TYPE 1 test cable

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ev-520-dEv-520-chEv-520-ukEv-520-f

Tabla de contenido