Special parameters
The special functions settings menu is accessed by pressing the mode selector button for 4 seconds
until F.00 appears on the display screen. Use the mode selector button and dial to change the values.
Finally, select the "END" function and press the mode selector button; the equipment will return to its
normal position when welding begins or after a while.
F00
Password to grant access to functions nº 11 and nº12. Select value "102".
With OFF mode selected, the equipment will turn off the user interface when it has not
F01
been used for 10 minutes, the equipment will return to normal operation when you start
welding again.
F02
Display Curve shows the actual state in TIG process welding.
F03
F03: Reverse function for the switches SW1, SW2 in TIG mode.
F04
Enable / disable remote control.
F05
% variation in the welding current balance in dual mode, only TIG 4T.
F06
Amps TIG start. Current applied to the initial arc during 100mS.
F07
PILOT ARC, in 4T mode, the Ihot is fixed to 5A.
F08
Not used in MMA equipments.
F09
16A activation mode.Only MMA equipments.
F10
Configure maxim input consumption level in KVA.
Specific parameters of the PFC equipment.
MMA welding assistance Enable. It's activated by default, it's only recommended to di-
F08
sable when specific electrodes are used such as cutting electrodes
Enable the visualization of the welding voltage as long as the equipment is welding in
F09
MMA.
F10
Configure maxim input consumption level in KVA.
SOLTER ICON equipments with PFC technology automatically reduced the maximum output welding
current in order to prevent excessive consumption in AC power networks whose voltage is below
190Vac. The maximum welding input voltage is reduced gradually from 190 VAC to 85 VAC.
The maximum input RMS consumption current cannot overpass 22A (rms) independently from AC
power network, therefore, power network overload is prevented.
The maximum welding current is different for TIG and MMA processes. When limiting mode is activa-
ted, main display blinks showing the maximum welding current at which the equipment is able to
weld. The equipment will not allow you to select upper values. In the following table, you will be able to
find the maximum welding current as function of supplying input voltage for the most common input
voltage ranges. The following table illustrates the corresponding maximum configurable amperage va-
lues for the most common power network voltages.