Piping Pneumatic Components And Wiring Electric Components - JUKI DLN-6390 Manual De Instrucciones

Ocultar thumbs Ver también para DLN-6390:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 214

4. Piping pneumatic components and wiring electric components

Perform piping of the pneumatic components and wiring of the electric components in accordance with the drawing below.
40033334 Accessories
40106208 Optional
40004065
40004041
0.5 MPa
PV150103000 Optional
Air pressure required for this sewing machine is 0.5 MPa.
Turn the dial to adjust the pressure to 0.5 MPa after
completion of piping.
Wiring diagram of pneumatic and electric components
SC-921
CN56
CN36
CN37
22951552 (Earth cord)
Black
White
Air tube (Black)
0.15 M
Optional
PC012401000 Optional
– 11 –
CN33
Black
DLN-6390-7 Machine main unit
Gray
Take care of color
when connecting
connectors.
40003754 Accessories
Air tube (Yellow)
Air tube (Blue)
Air tube (Green)
Air tube (Red)
Air tube (White)
Air tube (Black)
1.2 M
Air tube (Black)
1.3 M
Optional
Fix the air unit on the table with wood screws.
(For the fi xing position, refer to the drawing of table for
reference.)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dln-6390-7

Tabla de contenido