Datos técnicos y sugerencias
bibliográficas
Consumo nominal de corriente (V/Hz)
Frecuencia de trabajo (kHz)
Cantidad de llenado del depósito de agua (ml)
Consumo de agua pieza de mano Paro (ml/min)
Líquido de pulido Vector (μm)
Contenido de la bolsa de líquido de pulido Vector (ml) 200
Dimensiones (Al x P x An cm)
Peso (kg)
Sugerencias bibliográficas Vector
1. Braun et al. (2003) Subjective intensity of pain during the treatment of periodontal lesions with the
Vectorsystem
2. Christgau et al. (2007) Periodontal healing after nonsurgical therapy with a new ultrasonic device:
a randomized controlled clinical trial
3. D'Ercole et al. (2006) Effectiveness of ultrasonic instruments in the therapy of severe periodontitis:
a comparative clinicalmicrobiological assessment with currettes
4. Hoffman et al. (2005) Use of the Vector scaling unit in supportive periodontal therapy:
a subjective patient evaluation
5. Kahl et al. (2007) Clinical effects after subgingival polishing with a nonaggressive ultrasonic device in;
initial therapy
6. Kawashima et al. (2007) A comparison of root surface instrumentation using two piezoscalers and
a hand scaler in vivo
7. Kishida et al. (2004) Effects of a new ultrasonic scaler on fibroblast attachment to root surfaces:
a scanning electron microscopy analysis
8. Kocher et al. (2005) A new ultrasonic device in maintenance therapy: perception of pain and
clinical efficacy
9. Rupf et al. (2005) In vitro, clinical and microbiological evaluation of a linear oscillating device for scaling
and root planning
In vivo: 11 patients with chronic periodontitis. They had in total 120 single rooted teeth with a clinical attach
ment level and probing depth of 5 mm
10. Schwarz et al. (2003) Influence of fluorescencecontrolled ER: YAG laser radiation, the Vector system and
hand instruments on periodontally diseased root surfaces in vivo
11. Schwarz et al. (2003) In vivo effects of an ER: YAG laser, an ultrasonic system and scaling and root
planning on the biocompatibility of periodontally diseases root surfaces in cultures of human PDL fibroblasts
12. Sculean et al. (2004) Nonsurgical periodontal treatment with a new ultrasonic device (Vector ultrasonic
system) or hand instruments. A prospective, controlled clinical study
España y Portugal:
DÜRR DENTAL MEDICS IBERICA S.A.U.
C/Serra de la Salut, 11 – Nave 6
Pol. Ind. Santiga
08210 Barbera del Valles
Barcelona (España)
Tel.: +34 (0) 93 718 33 35
Fax: +34 (0) 93 729 62 32
www.durr.es
info@durr.es
Vector Paro
230, 50/60
25–35
600
aprox. 30
tamaño de grano medio: <10
16 x 21,5 x 25,5
2,5
América del Sur:
Dürr Dental do Brasil
Av. Carlos Gomes, 126/501
90480000 Porto Alegre RS
Phone: +55 51 3207 7499
Fax: +55 51 3207 7499
u.campregher@durrdental.com.br
www.durrdental.com.br