BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.3

Process data

The BIP outputs 2-byte process data via the IO-Link
interface. The process data structure is described in the
Smart Sensor Profil Ed.2.
Bit offset
SDCI
Transmission
direction
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Description
Type
Value
Magnet out of range
1)
Tab. 6-3:
Process data
Structure of byte 0
Bit Name
7
System error
6
OoR no data
5
OoR out of range
4
Unsafe value
3
SSC4
2
SSC3
1
SSC2
0
SSC1
Tab. 6-4:
Prozessdaten – Byte 0
12
english
IntegerT(16)
Measurement value
Bytes 3
Measurement value
INT16 (signed integer)
Nominal values are 0...17000,
Out of Range
–32760...+32760
1)
No measurement = 32764
Function
System reports
overtemperature
The magnet lies outside the
detection range
The magnet lies outside the
measurement range
Not supported
Switching information of the
fourth switching point
Switching information of the
third switching point
Switching information of the
second switching point
Switching information of the
first switching point
16
IntegerT(8)
Scale
Bytes 2
Bytes 1
Scale
INT8
–6 (µm)
Measurement value
The measurement value represents the position of the
magnet in μm and consists of a signed 16-bit value.
Fig. 6-1:
Measurement value and areas
If the magnet lies outside the measurement range, the
process data variable is assigned the following values:
No Measurement data 32764
Out of Range positive 32760
Out of Range negative –32760
The detection range is 17000 µm at delivery (detection
range = measuring range).
8
8 bits
Vendor specific
Bytes 0
BOOL
0
Detection range
Measuring range
Position
0