BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
7
Technical data
The technical data, in particular the repeat accuracy,
applies after a warm-up period of 15 min.
7.1
Accuracy
Linearity range S
l
Linearity error
Effective distance S
e
Repeat accuracy
7.2
Ambient conditions
Ambient temperature T
a
Storage temperature
Temperature drift max. of full scale
Vibration
per EN 60068-2-6
Degree of protection per IEC 60529 IP67
Shock rating
per EN 60068-2-27
Contamination scale
7.3
Power supply
Operating voltage U
, stabilized
B
Rated operating voltage U
No-load current I
at U
0
e
Residual ripple
Rated insulation voltage U
Mains rated frequency
Short-circuit protection
Protection against device mix-ups
Reverse polarity protection
28
english
0...17 mm
≤ ±250 µm
8.5 mm
±50 µm
1)
–25...+70 °C
−40...+85 °C
±3 %
55 Hz, 1 mm
amplitude,
3 × 30 min
30 g/11 ms
3
18...30 V DC
2)
24 V DC
e
≤ 20 mA
≤ 10 % (of U
)
e
75 V DC
i
DC
yes
yes
yes
7.4
IO-Link interface
Specification
Transfer rate
Process data
Position value at S
l min
Position value at S
l max
Data format
Cycle time
Master-device process data
Device-master process data
7.5
Mechanical data
Housing material
Active surface material
Connection type
Tightening torque
Cable coating material
Cable diameter
Cable, number of wires
Wire cross-section
Bending radius, fixed routing
For UL: Use in enclosed spaces and up to a height of 2000 m above sea
1)
level.
For UL: The BIP must be connected externally to a power-limited circuit
2)
according to UL 61010-1 or a power source of limited output according
to UL 60950-1 or a power supply with Protection Class 2 according to UL
1310 and UL 1585.
IO-Link 1.1
38.4 kBaud (COM2)
4 bytes
0 µm
17000 µm
16 bit signed integer
≥ 3 ms
0 bytes
4 bytes
PA
PA
Cable without/with
connector
0.5 Nm
PUR
≤ 3.5 mm
3
0.14 mm
2
≥ 3 × cable diameter