BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.10.6 Access locks (Device Access Locks)
Using this standard parameter, it is possible to activate or
deactivate certain functions of the IO-Link device.
In BIP, there is the option to lock the function of the
parameter manager and the button. To do so, the
respective bit of the 2-byte value must be set to 1 (locked).
In order to unlock the function again, the bit is set to 0.
Bit 0
Lock parameter access
(supported)
Bit 1
Lock parameter management
(supported)
Bit 2
Locking the button
(not supported)
Bit 3
Lock local user interface
(not supported)
Bit 4...15
Reserved
Tab. 6-13: Locking parameter data
6.10.7 Profiles and functions (ProfileCharacteristic)
This parameter indicates which profile of the IO-Link device
is supported.
–
Subindex 1 (DeviceProfileID):
0x000A (Measuring Sensor standard resolution)
–
Subindex 2 (DeviceProfileID):
0×4000 (identification and diagnosis according to
common profile)
–
Subindex 3 (FunctionClassID):
0×8001 (SSC function class)
–
Subindex 4 (FunctionClassID):
0×8004 (teach channel)
www.balluff.com
6.10.8 Process data structure (PD Input Descriptor)
This parameter describes the composition of the process
data used.
Every part of the process data is described by 3 bytes.
Subindex
Values
0x01
1
0x04
0x00
0x01
2
0x04
0x04
0x03
3
0x08
0x08
0x03
4
0x10
0x10
Tab. 6-14: Process data structure
Using subindex 0, the complete process data description
can be read out (see section Process data on page 12).
Description
Set of Boolean
4-bit length
0-bit offset
Set of Boolean
4-bit length
4-bit offset
Signed integer
8-bit length
8-bit offset
Signed integer
16-bit length
16-bit offset
english