BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.5

System parameters

Index
Parameters
hex (dec)
0x000D
ProfileCha-
(13)
racteristic
0x000E
PD Input
(14)
Descriptor
Tab. 6-7:
System parameters
14
english
Subindex
Parameters
hex (dec)
0x01 (1)
DeviceProfileID
0x02 (2)
0x03 (3)
0x04 (4)
0x01 (1)
SSC1, SSC2,
SSC3, SSC4
0x02 (2)
0x03 (3)
PDV1
0x04 (4)
PDV2
Data format
Access
Value
range
UINT16
Read only
0x0001
0x000A
0x4000
0x8001
OctetStringT3 Read only
0x010400 Switching channel
0x010404 Out of range, error
0x030808 Measurement value-
0x031010 Measurement value/
Comments
Smart Sensor Profile
Measuring Sensor
Profile (16-bit),
inherent Smart Sensor
Profile.
Common Profile
Binary Data Channel
status
multiplication value
position value

Publicidad