Diagnostic data

The BIP reports diagnostic data (events) to the controlling
system (see Tab. 6-22), or the controlling system can read
out the status using the diagnostic parameters.
6.15.1 Diagnostic parameters
Index
Subindex
0x0024 (36)
0
0x0025 (37)
0
Tab. 6-22: Diagnostic parameters
6.15.2 Event list
Event code Expression Meaning
0x8D02
Error
0x8D03
Error
0x8D04
Error
0x4210
Warning
0x4220
Warning
0x4000
Error
Tab. 6-23: Event list
26
english
Parameter
Size
Device Status
1 Byte
Detailed Device
18 Byte
Status
OUT OF RANGE PLUS – The magnet is located outside of the detection range. No valid data
is output. The transmitted process data value is 32760.
OUT OF RANGE MINUS – The magnet is located outside of the detection range. No valid
data is output. The transmitted process data value is –32760.
NO MEASUREMENT DATA – No magnet detected. No valid data is output. The transferred
process data value is 32764.
DEVICE TEMPERATURE OVERRUN (see section 6.10.2) – The configured upper temperature
threshold is exceeded.
DEVICE TEMPERATURE UNDERRUN (see section 6.10.2) – The configured lower
temperature threshold is not met.
TEMPERATURE OVERLOAD – The temperature has exceeded the specified maximum
temperature (+125°C). The heat source must be removed.
Access
Values
Read Only
0 = Normal state
2 = Warning
4 = Error
Read Only
Up to 3 active events:
1st byte event type (0 = No event,
0xE4 = Warning, 0xF4 = Error)
2nd and 3rd byte event code (see Sec. 6.15.2)