Water leakage from pump
shaft (rotating joint between or defective
the pump and the motor)
The motor does not start
The motor stops
*
: This type of repair requires the intervention of qualified personnel. Contact your Jacuzzi
ice Centre.
FOR INSTALLATION, MANAGEMENT AND USE OF THE MAXIJIACUZZI
TIONS CONTAINED IN THIS MANUAL.
It is the responsibility of the installer/owner to ascertain compliance with specific local regulations prior to
installation. Jacuzzi Europe S.p.A. gives no guarantee in this respect and declines all responsibility regard-
ing the compliance of the installation performed.
Water leaks on the suction line
Low water level
Motor bearings worn or
faulty
The impeller rubs against
Pump body
solid foreign bodies inside
the pump
Pump seal worn
No power
Mains switch
is triggered
Voltage too low
The residual current operated circuit
breaker (RCCB) is triggered
Incorrect or faulty connections
Shaft and impeller blocked
Motor windings burnt
Faulty contact on motor
start-up
The function has ended
Overload
Power supply cables
inadequate
Locate the leak and repair it
Add water up to the normal level
*
*
*
*
Turn on the mains switch
Turn on the switch
Contact an electrician or
the electric power utility
Reset the RCCB
*
*
*
*
Press the relative button on the display once again
Leave the motor to cool and
the problem should disappear.
If it persists, see
Consult an electrician
®