Descargar Imprimir esta página

Guinaz G3230 Guia De Instalacion página 15

Placas de calle y grupos control audio digitales con visor

Publicidad

The connection between the street panel and the door opener is
executed through two cables (NO bushing insulators and – audio
control unit). Bushing insulators +12 and C are to be connected
between each other with a cable. An external push button can
also be connected to bushing insulators C and NO of the audio
control unit to activate the door opener. The activation time of the
door opener when the external push button is activated is not in
timer mode; that is to say, the door opener can only be activated
when the external push button is held down.
Monitors have an auxiliary potential free pushbutton to activate
functions other than those of the installation. The contacts of
this pushbutton are terminal blocks 12 and 13 of the monitor.
M1934
POWER SUPPLY CABLE.
SIGNAL CABLE.
Do no shut-off the resistance
COAXIAL CABLE.
F1330
M1934
Shut-off the resistance
Configuration for
coaxial cable.
Telephone number pad
Main internal
Auxiliary door opener push-button
Street panel
Configuration of
Number (No. 1)
street panel
Connection with straps:
Door opener (12 Vdc, max 400mA)
Please see point 4.9 to install alternating current door opener.

Publicidad

loading

Este manual también es adecuado para:

G3240