Instructions For Use; Description Of The Hectar Counter; Use And Maintenance; Technical Data - GASPARDO HCS Instrucciones Empleo Y Para El Montaje

Tabla de contenido

Publicidad

ENGLISH

3.0 INSTRUCTIONS FOR USE

3.1 DESCRIPTION OF HECTARE COUNTER HCS
GASPARDO hectare counters HCS are the ideal equipment for
counting and viewing the tilled area (partial and total) as well as
for counting the hours of operation.
From software version 2.0 on, the GASPARDO HCS hectare
counter is equipped with the Self-calibration of constant "C" fun-
ction (see page 16).
A) 5-digit backlit display showing the total area, partial area and
the hours of operation.
B) Display section showing the partial area counter.
C) Display section showing the total area counter.
D) Key for partial area counter selection/resetting: during program-
ming this key is pressed to increase the value of the selected
constant.
E) ON/OFF button: hold this button pressed with the monitor on
to access the programming phase.
F) Key for total area counter selection/resetting; during program-
ming this key is pressed to reduce the value of the selected
constant.
We recommend installation of the monitor opposite the operator
so that it is easier to use during the working cycle.
Hectare counters HCS enable viewing of the following:
- total area tilled: 0000.0 ÷ 9999.9 Ha with 0.1 Ha pitches; if 9999.9
Ha is exceeded without resetting, the counter automatically starts
from 000.00 again.
- partial area tilled: 000.00 ÷ 999.99 Ha with 0.01Ha pitches; if
999.99 Ha is exceeded without resetting, the counter automati-
cally starts from 000.00 again.
- hours of operation: 0000.0 ÷ 9999.9 hours with 0.1 hour pitches
(6 minutes); if 9999.9 hours are exceeded without resetting, the
counter automatically starts from 0000.0 again. The hours of
operation are increased ONLY if pulses are received from the
speed sensor.
B
D
fig. 4
14

USE AND MAINTENANCE

A
E
F

3.2 TECHNICAL DATA

HCS
- Power supply voltage
- Max. energy consumption
- Fuse
Functioning characteristics
- Protection degree
- Mechanic vibrations resistance
Functioning conditions
- Room temperature
- Weather conditions
Transport and storage
- Temperature
Speed sensor
- Power supply voltage
- Max. working frequency
- Working temperature
- Max. operation distance
- Protection degree
Cables
- Sensor connector
- Power connector
- Functioning temperature
The technical data and the models provided must be consi-
dered as non binding. We reserve the right to change them
without notice.
C
10÷16 Vdc
250 mA
Internal, Self-restoring
IP 65
2 G
-20°C / +70°C
Relative humidity 90%
-25°C / +85°C
220 V (max)
230 Hz (max)
-20/+80 °C
15-20 mm
IP67
AMP Super seal 2-way
3 poles
-20°C / +80°C
cod. G19502721