Plumbing Requirements - Scotsman C0522R Manual De Instalación

Ocultar thumbs Ver también para C0522R:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Plumbing Requirements

All models require connection to cold, potable
water. A hand actuated valve within site of the
machine is required. There is a single 3/4 gas
BSPP inlet water connection.
Warning: All models require connection to
potable water.
Water Filters
Install a new cartridge if the filters were used with a
prior machine.
All models require drain tubing to be attached to
them. There is a single ¾" FPT drain fitting in the
back of the cabinet.
Install new tubing when replacing a prior ice
machine, as the tubing will have been sized for the
old model and might not be correct for this one.
1. Connect water supply to water inlet fitting.
Water Supply
Remote Condenser Models - Installation Manual
2. Connect drain tubing to drain fitting.
3. Route the drain tubing to building drain. Follow
Use rigid drain tubes and route them separately –
do not Tee into the bin's drain.
Vent the reservoir drain. A vertical vent at the back
of the drain, extended about 200 mm will allow the
gravity drain to empty and also keep any surges
during draining from discharging water.
Horizontal runs of drain tubing need a 20 mm per
fall per meter of run for proper draining.
Follow all applicable codes.
Water Supply and Drain Illustration
June 2007
Page 13
C0522 through C1030
local codes for drain air gap.
Water Supply Connection
Drains Must Be Separate
Drain Must Be
Vented