Display control
10.2. Display
The main display shows different inverter data:
A.
Current date, YYYY-MM-DD.
B.
Percentage of nominal power and reason for power reduction*. In the event that there is no power
reduction and the inverter operates at 100% of its nominal power, this percentage is not shown on the
display.
C.
Current time, hh:mm.
D.
Voltage and power of the PV array. Both pieces of data are displayed alternately.
E.
Power, voltage and current fed to the public grid.
F.
Wattmeter for instantaneous self consumption. This symbol is only shown if the inverter is configured to
work in self consumption mode. If it flashes, this is due to a communication failure with the wattmeter.
Pressing the key
takes you to the main menu. Pressing the key
displays the energy graph for the last 24 days.
* The reasons for power reduction are as follows:
T: Temperature. The inverter is limiting the power due to the temperature.
C: Communications. The inverter is limiting the power after having received a reduction setpoint through
communications.
F: Grid frequency. The inverter is limiting the power due to the grid frequency variation. Applicable
according to selected regulations.
V: Grid voltage. The inverter is limiting the power due to the grid voltage variation. Applicable according
to selected regulations.
Q: Reactive priority. The inverter is limiting the power due to the injection of reactive power.
A: Configuration. The inverter is configured to limit its power (see section "10.8. Configuring the power
limit").
R: Initial connection ramp. The inverter is limiting the power after a reconnection to the grid. Applicable
according to selected regulations.
S: Self consumption mode. The inverter is limiting the power due to functioning in self consumption
mode.
M: Reserved mode.
ABE2011IQM01_C - Installation and Operation Manual
A
B
2016-01-11
2016-01-11
D
C
10:17
10:17
F
E
displays the daily power graph. Pressing
Ingeteam
DE
EN
ES
FR
IT
PT
91