Preface; Introduction; Identification Of The Product; General Description - PLYMOVENT ControlGo Manual De Instalación Y De Uso

Ocultar thumbs Ver también para ControlGo:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

pREFacE

Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
pictograms and symbols
The following pictograms and symbols are used in this manual:
tip
Suggestions and recommendations to simplify
carrying out tasks and actions.
attENtioN
A remark with additional information for the user. A
remark brings possible problems to the user's
attention.
caUtioN
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WaRNiNG
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
caUtioN
Denotes risk of electric shock.
text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "•" (bullet point) describe steps to
perform.
product indications / abbreviations
Product type:
Equals to:
- ControlGo/Panel
Panel
- Control/SlaveBoard
SlaveBoard
- MDB GO
MDB
- SCS GO
SCS
- EDS GO
EDS
- MultiDust Bank
MDB
1

iNtRoDUctioN

1.1

Identification of the product

The identification plates contain, among other things, the
following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2

General description

ControlGo of Plymovent is an intelligent control panel,
including the required connection cables. This system controls
the compressed air valves of the connected filter system MDB,
SCS and EDS and the connected extraction fan.
1.2.1
ControlGo + MDB
Fig. 1.1
A
Filter system MDB
1
B
SlaveBoard
2
C
Panel [control panel]
D Fan control equipment (refer to paragraph 1.3)
E
Extraction fan (refer to paragraph 1.3)
1.
Shown: rear of the filter system
2.
Integrated on the rear of each filter module
0000112607/170717/0 ControlGo
A
Fig. 1.1
ControlGo + MDB
1.2.2
ControlGo + SCS / EDS
Fig. 1.2
A
Filter system SCS / EDS
B
Panel [control panel]
C
Fan control equipment (refer to paragraph 1.3)
D Extraction fan (refer to paragraph 1.3)
A
Fig. 1.2
ControlGo + SCS / EDS
1.3
product combinations
1.3.1
Required products
To operate the system, selection of the following products is
necessary:
Extraction fan
- Plymovent SIF
(Outdoor)
Mounting frame
- Plymovent FRAME SIF
Fan control equipment
Recommended way:
- Plymovent VFD/Panel3
(frequency inverter)
Other options:
- Other type of frequency
inverter (third party)
- Star-delta switch
- Other type of motor
starter
3.
Including main switch to de-energize the entire filter system, thus complying
with CE safety requirements. Additionally needed: pressure transmitter
PT-1000 or PT-2500.
B C
D
E
B
C
D
specific type and motor power
depends on the configuration
specific type depends on the
selected extraction fan and
configuration
specific type depends on the
selected extraction fan
fan start/stop with optional
alarm feedback only
fan start/stop with optional
alarm feedback only
e.g. Direct online (DOL)
EN - 3

Publicidad

Tabla de contenido
loading

Productos relacionados para PLYMOVENT ControlGo

Tabla de contenido