Depending on the specific configuration of the filter system,
some of the connections on the PC board inside the Panel
remain unused. The PC board contains detachable screw
terminal blocks ("connectors").
Table I on page 77 gives an overview of the necessary and
optional cables
that you need to install the system.
14
caUtioN
- Shorten excessive cable lengths. A coil or bundle
of cables can cause electromagnetic interference.
- Make sure that you connect the wiring in the
correct way. Wrong wiring may cause permanent
damage to the PC board.
- Use cable glands to insert cables into the Panel.
- Keep the blanking plugs on the cable glands that
are not in use to avoid pollution of the Panel.
- For all connections, also refer to the separately
supplied electrical diagram.
- Refer to Table II on page 78 for a specification
of the digital inputs (high/low).
General instructions to connect a cable to a
certain connector (unless otherwise stated)
Wire stripping:
A
B
(1) Put the cable through a cable gland M16 into the
Panel.
(2) Carefully remove the connector from the PC board.
Pull the connector in a horizontal direction.
Cut the cable to the correct length and strip the wires.
1
Shielded cables only:
Put a shrink tube on the drain wire (A) and the cable
jacket (B).
4
Heat shrink the shrink tube with a heat gun (C).
A
B
B
3
14. Recommended cable specifications; use cables with a max. wire diameter 1,5
mm² (AWG 16)
0000112607/170717/0 ControlGo
All cables:
Detachable screw terminal block ("connector")
Wire bridges
The PC board is provided with a number of wire bridges.
mm
in.
A
a
50
2
B
6
¼
B
C
D
E
Fig. 4.6 Wire bridges
4.4.1
2
To install the mains cord, do the following.
Fig. 4.7
5
C
C
15. Size M20
1
(3) Put the wires into the connector.
(4) Tighten the screws.
(5) Put the connector back on the PC board.
Tighten the cable gland.
4
3
connection
Remark
Digital input 1-5
Digital input 1-5
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
A
IN 4
internal filter pressure sensor
(refer to paragraph 4.4.10)
COM1 to GND
do not remove the wire bridge!
Digital input 6-12
Digital input 6-12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
C
C
IN 6
do not remove the wire bridge!
IN 11
external alarm signal (refer to
paragraph 4.4.7)
COM1 to GND
do not remove the wire bridge!
Mains cord (cable #3)
caUtioN
High voltage connection
Put the mains cord (B) through the metal cable gland
into the Panel.
Connect the mains cable to the terminal block (A).
Tighten the cable gland.
2
5
B
B
D
E
D
E
(C)
15
EN - 7