filter lifespan while minimizing the required amount of
compressed air, ControlGo applies progressive filter cleaning.
This means that the filter cleaning intensity is adapted to the
actual pressure over the filter cartridges, according to certain
preset threshold values.
threshold values MDB:
threshold
pressure
value
1
800 Pa
2
1000 Pa
3
1200 Pa
4
1400 Pa
1300 Pa
1600 Pa
During one cleaning cycle each filter cartridge gets one
compressed air pulse.
threshold values ScS and EDS:
threshold
pressure
value
1
1000 Pa
2
1200 Pa
3
1400 Pa
4
1600 Pa
1500 Pa
2000 Pa
During one cleaning cycle the filter cartrigdes are cleaned
sectionwise by compressed air pulses
cleaning cycles take place after shutdown of the fan.
2.2.2
Forced filter cleaning
MDB
If the pressure drop has remained below 800 Pa (3.2 in. WG)
during 30 running hours of the system, one offline filter
cleaning cycle takes place.
ScS and EDS
If the pressure drop has remained below 1000 Pa (4 in. WG)
during 30 running hours of the system, three offline filter
cleaning cycles take place.
3

SaFEty iNStRUctioNS

General
The ControlGo is delivered as part of a filter system MDB, SCS
or EDS of Plymovent. The safety instructions written in the
related manuals apply to the ControlGo as well.
intended use
6
The product has been designed exclusively as control
equipment for use with a filter system type MDB, SCS and of
Plymovent with the connected extraction fan. Using the
product for other purposes is considered contrary to its
intended use. The manufacturer accepts no liability for any
5.
40 pulses per cycle
6.
"Intended use" as explained in EN-ISO 12100-1 is the use for which the
technical product is suited as specified by the manufacturer, inclusive of his
directions in the sales brochure. In case of doubt it is the use which can be
deduced from the construction, the model and the function of the technical
product which is considered normal use. Operating the machine within the
limits of its intended use also involves observing the instructions in the user
manual.
0000112607/170717/0 ControlGo
Offline
Delay
online
cycles
cycles
2
4 h
4
4
2 h
8
6
1 h
12
continuous filter cleaning
pressure fallback
filters clogged
Offline
Delay
online
cycles
cycles
1
4 h
2
2
2 h
4
3
1 h
6
continuous filter cleaning
pressure fallback
filters clogged
. Two additional offline
5
A
damage or injury resulting from such use. The product has
been built in accordance with state-of-the-art standards and
recognised safety regulations. Only use this product when in
technically perfect condition in accordance with its intended
use and the instructions explained in the user manual.
4

iNStaLLatioN

4.1
tools and requirements
You need the following tools to install the products:
- basic tools
- tools for electrical connections
4.1.1
To be sourced locally
Mounting material
- to install the Panel to the wall (hardware max. Ø 10 mm)

Connection cables

- refer to Table I on page 77 (#3 to 13) for the cable
specifications
If necessary:
- additional cable glands M16
4.2
Unpacking
Make sure that the system is complete. The package contains:
4.2.1
ControlGo/Panel
- Panel (control panel)
- double-bit key
- mounting bracket (4), incl. mounting material
- pneumatic hoses, incl. mounting material:
- 2x10 m (for filter pressure)
- installation and user manual
- electrical diagram
- UL compliance sticker
4.2.2
Connection cables
Fig. 4.1
A
Panel  SlaveBoard cable
plug and heat shrinking tubes
B
SlaveBoard  SlaveBoard cable
[cable #1]
A
Fig. 4.1 Connection cables
7.
E.g. heat gun, cable stripping tool
8.
The type of mounting material depends on the wall type
9.
Number and type of cables depends on the selected options and control
equipment
10. For use in North America
11. MDB only
7
:
8
:
9
10
, incl. cable gland, termination
11
, incl. cable glands
11
A
B
B
B
C
[cable #2]
C