EN
16
Technical data
Description
Mains voltage [V]
Rated current [A]
Grid frequency [Hz]
Network types
EMC class
Overvoltage category
Protection class
IP-protection class
Protection against mechanical impact
Protective devices
Fixation type
Cable feed
Power supply conductor cross section
Charging cable with charging coupling
Mains connection terminal
Output voltage [V]
Max. charging power [kW]
Ambient temperature [°C]
Storage temperature range [°C]
Display
Lock
Altitude [m]
Permissible relative humidity [%]
Weight [kg]
10
Data
230 / 400 AC
8A, 10A, 13A, 16A, 20A, 25A, 32A (single-phase, 3-phase), split phase (L1+L2, without N),
max. 16A possible with 11 kW charging station
50
TT / TN (single- and 3-phase) / IT (1-phase)
Emitted interference: class B (residential, business, commercial areas)
Immunity: industrial areas
III as per EN 60664
I
IP54
IK08
Earth leakage circuit breaker RCD of type A & circuit breaker. See chapter 8 Installation and electrical connection.
Wall and base mounting (permanently connected)
Mounted on-wall or in-wall
Depending on the cable and type of installation, the recommended minimum cable cross-section for a standard installation is:
6 mm² (for 16 A)
10 mm² (for 32 A)
Type 2 according to EN 62196-1 and EN 62196-2
Connection cable:
– rigid (min.-max.) 2.5-10 mm²
– flexible (min.-max.) 2.5-10 mm²
– flexible (min.-max.) with wire end ferrule 2.5-10 mm²
230 / 400 AC
11 kW or 22 kW (depending on factory configuration)
-30 to +55 (without direct solar radiation)
-30 to +80
LED element
Key-operated switch set to start charging
max. 3000 (above sea level)
5 up to 95; non-condensing
11 kW
4.5 m: 4.6 kg
7 m: 5.3 kg
OI II Webasto Pure