Connection To Waterworks; Steam Connection; Steam Trap - Firex PMKIV Serie Manual De Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Marmita a vapor
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2.1.2. CONNECTION TO WATERWORKS

− The appliance is equipped with a mixing tap to fill the cooking vat with water.
− Install a cut-off valve on the line before the appliance.
− Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure
regulator on the line before the appliance.
− Water connections to ½" are fitted in the lower part on the right-hand side of the
appliance.
− Make connections according to regulations currently in force.
Warning! : during operation, steam pressure at inlet can reach a maximum pressure
of 0,45 bar.
− Installation shall be performed only by qualified personnel in conformity with current
regulations.
− For the maximum efficiency, deliver dry steam with a maximum pressure of 0,45 bar
into the steamers.
− Water and steam inlet piping shall be connected in the lower part on the right-hand
side of the appliance.
− Before connecting the last piece of piping to the steamer connections, it is advisable to
let some water and steam to flow through them to eliminate any iron residues from
inside.
− All the steam supply piping shall be insulated to prevent heat dispersion.
− Install a steam trap on the kettles.
− The ¾" connections is fitted in the lower central part of the kettle (Mod. 50lt. – 100lt. –
150lt.).
− The 1¼" connections is fitted in the lower central part of the kettle (Mod. 200lt. – 300lt.
– 500lt.- 170lt. – 270lt. – 370lt.).
− This device drains automatically any condensate that develops in the jacket.
− A nonreturn valve must be installed if the condensate returns to the steam boiler. The
maximum back pressure admitted is 0,2 bar.
Instruction manual for installation, maintenance and use
Steam heated kettles PMKIV...

2.1.3. STEAM CONNECTION

2.1.4. STEAM TRAP

9 di 19