Cold Wire Tig Process; Quality Control; Test - Cebora ARCO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12�2 Cold wire TIG process
WinTIG range power sources can also manage the cold wire TIG process in combination with the WF5 COLD WIRE
feeder unit Item 1649.
See Figure 3 for the connection procedures.
To enable the TIG cold wire process, proceed as follows:
To choose the wire feeder parameters, select: Menu -> Cold Wire Parameters
For all cold wire process settings, refer to the manual for Item 1649 code 3301059.
The cold wire process can also be used in conjunction with the Plasma Welding process, both in AC and DC modes.
13

QUALITY CONTROL

Please refer to the user manual for the accessory Item 273. For production mode, please refer to the manual for Item
273.
14

TEST

Select sector T – Fig. 4 to perform the following tests:
- Menu -> Accessories
- use B to select Wire Feeder Unit and confirm:
OFF Cold wire unit disabled
ON Cold wire unit enabled
To perform the shielding gas test, press the pushbutton:
duration of the current test is indicated on the right
[Wire Inch/Retract if cold wire feeder Item 1649 is present: press
pushbuttons:
Wire feed speed is shown on the right
Gas Test if Plasma Console item 465.01 is installed, duration of the
current gas testing process is shown on the right.
To perform the plasma gas test, press the pushbutton:
To perform the shielding gas test, press the pushbutton:
the
101/107

Publicidad

Tabla de contenido
loading

Tabla de contenido