Cebora ARCO Manual De Instrucciones página 72

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The parameters set out in Tab. 1, the ignition modes (HF, Lift), start management (2 stroke, 4 stroke etc.) and the pulse
parameters can be set in the section Menu->Parameters->Process Parameters.
The gas flow parameter indicates the setpoint of the shielding gas if Kit Item 436 is present.
In the absence of Kit Item 436, this kit is used to count the gas delivered in weld counters (weldments).
The menu includes a further item Advanced Parameters which includes advanced TIG process parameters. To use
these parameters, contact Cebora technical assistance.
(**) The EVO START parameter generates a set of pulses at the start of the welding process to improve the joining of
the two strips of material to be welded. The setting for this parameter depends on the geometrical shape of the parts
to be welded.
72/107

Publicidad

Tabla de contenido
loading

Tabla de contenido