ERROR CODES

Error management is divided into two categories:
Hardware errors [E]. These cannot be reset and require the power source to be restarted. They are displayed on the
screen with a red background.
Alarms [W] linked to an external condition that can be reset by the user and does not require the power source to be
restarted.
These are displayed on the screen with an amber background.
Code
Type
3
[E]
General fault error detected by the power source
internal slave board
4
[E]
Error on database
6
[E]
Communication error detected by master panel
board on CAN-bus
7
[E]
Communication error in CAN2.
8
[E]
Wire feeder not connected error
9
[E]
Panel Circuit not connected
10
[E]
Power output nil (I=0A, V=0V)
11
[E]
Overload at output
13
[E]
Login time too long
14
[E]
Undervoltage error detected on inverter control
board.
20
[E]
Interlock signal absent
22
[E]
Hardware key not readable
23
[E]
Earth cable leakage
25
[E]
Excessive primary winding current error
26
[E]
Time not set or battery flat
28
[E]
Fan malfunction
30
[E]
Output current sensor offset reading problem

Error Description

Action
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source on and off. If the error
persists, contact technical assistance.
Switch the power source on and off. If the error
persists, contact technical assistance.
Check the connection between CN2 and robot
interface. Switch the power source on and off. If
the error persists, contact technical assistance.
Check the connection leading from power
source CN1 to wire feeder Item 1649. Switch the
power source on and off. If the error persists,
contact technical assistance.
Check the connection leading from power
source CN3 to remote panel Item 438. Switch
the power source off and on. If the problem
persists, contact technical assistance
Hardware error, contact technical assistance.
Probable break in inverter circuit of primary
winding
Hardware error, contact technical assistance.
Hardware error, contact technical assistance.
Check machine supply voltages. If the problem
persists, contact technical assistance.
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source on and off. If the error
persists, contact technical assistance.
Switch the power source on and off. If the error
persists, contact technical assistance.
Switch the power source on and off. If the error
persists, contact technical assistance. Probable
break in output diodes or primary winding
inverter circuit.
Switch the power source on and off. If the error
persists, contact technical assistance.
Check there are no mechanical blockages in the
rotating parts of the fan. If the problem persists,
contact technical assistance.
Switch the power source on and off. If the error
persists, contact technical assistance.
105/107