Accessories Menu; Cooling Unit - Cebora ARCO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9�3

Accessories menu

Activate the various accessories available in the power source from the following menu
If accessories are present in the welding system, they must be connected to the power source before powering
up. Connecting/disconnecting accessories while the power source is switched on leads to system malfunctions
and under extreme circumstances could compromise the integrity of the welding system. CEBORA SpA does not
provide warranty coverage for inappropriate use of the welding system
To access the Accessories menu, select Menu->Accessories
9�3�1 Cooling unit
The cooling unit to be used with the WinTIG power source is Item 1683 - GRV12.
394.XX is optional on power sources Item 380.XX, while it is standard on other power sources Item 395.XX, Item 396.
XX and Item 381.XX�
The status bar S always shows the cooling unit icon
ON, OFF, AUTO.
NOTICE
and unit status is shown in the upper part of the icon:
Encoder B is used to select/activate the operating mode:
OFF Cooling unit disabled.
ON Cooling unit always on.
AUTO Cooling unit operates in synchrony with the welding process
83/107

Publicidad

Tabla de contenido
loading

Tabla de contenido