4�4
TIG parameter settings table
Process parameters can be set directly using the following sequence:
♦
press B
♦
turn B to select a single parameter
♦
press B to enter parameter modification mode (the parameter turns red)
♦
turn B to select the desired value
♦
press B again to exit modification mode.
(*)
Item
I2_max
380
381
394
395
396
Description
Pregas duration
EVO START (**)
(TIG DC HF)
Hot Start AC
(TIG AC HF)
(TIG MIX HF)
First Level Current
First Level Duration
Initial Ramp Duration
Main Current
Intermediate current
Final Ramp Duration
Crater Current Duration
Crater Current
Duration
postflow
340A
500A
270A
340A
450A
Min�
DEF
0.1
0.1
OFF
OFF
0.1
1.6
3
25
0
0
0
1.0
3
100
5
50
0
1.0
0
0
3
10
0.1
10
Table 1
Max
UoM
Sol�
10
s
0.1
1.0
s
0.1
6.0
mm
0.1
I_SET
A
1
30
s
0.1
10
s
0.1
I2_max(*)
A
1
I2_max(*)
A
1
10
s
0.1
10
s
0.1
I_SET
A
1
50
s
1 (0.1-25) s
5 (25-50) s
71/107