SKSFD3604P – 36" INTEGRATED FRENCH DOOR REFRIGERATOR
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
"
1 3/8
Electrical location
is not available
NOTE
depth adjacent cabinets.
(19 mm) beyond 24" (610 mm) depth adjacent cabinets.
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
A 115V, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch
circuit or circuit breaker must be used in case of requiring disconnect after installation. Install a
properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation.
The water pressure must be between 20 and 120 psi.
accommodate a bend leading into the water line connection.
Install a shut-off valve between the icemaker water valve and the cold water supply in the home.
36"
finished width
4"
(102 mm)
finished
return*
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
(35mm)
"
1 3/8
(35mm)
Electrical location
is not available
(914 mm)
25"
(635 mm)
min. depth
flush install
24"
(610 mm)
min. depth
proud install
84"
(2134 mm)
9