DESCRIPTION

3 .1 General description

This device is a compact pumping station. SANICUBIC® 1 and SANICU-
BIC® 1 WP are pumping stations specially developed for individual use
(detached house or small commercial premises). SANICUBIC® 2 Classic
and SANICUBIC® 2 Pro are pumping stations specially developed for indivi-
dual, commercial and small community use (small buildings, shops, public
places). SANICUBIC® 2 XL is a pumping station specially designed for com-
munity use (professional buildings, restaurants, industries, schools, hotels
or shopping centres). These devices comply with the EN 12050-1 standard
(pumping station for waste water containing faeces) as well as the European
directives on construction products, electrical safety and electromagnetic
compatibility. DoP available on our website in the product file («Diagrams
and technical data sheet» tab).

3 .2 Scope of supply

Depending on the model, the following components are provided:
• Sump tank with 1 or 2 pumps and 3 level sensors, depending on the model
• Remote control box (except SANICUBIC® 1)
• Wired or HF alarm unit, depending on the model
• Check valves
• Mounting kit (screws, pegs)
• Connecting sleeves for inlet, discharge and ventilation piping
• Clamps for the connecting sleeves
• Vent turbine

3 .3 Rating plate

Examples:
Pumping station
1
2
9
8
1
Name of the pumping station
2
Power consumption of the motors
3
Power supply
4
Frequency
5
Protection index
6
Date of production
7
Identification number
8
Declaration of performance reference (DoP)
9
Type of certification
Control box
2
1
1
Name of the pumping station
2
Name of the control box
3
Power supply
4
Phase type
5
Frequency
6
Protection index
7
Date of production
3
4
5
6
7
4
3
5
6

3 .4 Design and operating mode

1
5
1
8
6
Table 2: SANICUBIC® 2 Pro illustration
1
Inlet
2
Inlet
3
Waste pipe
4
Ventilation opening
5
Level sensor (dip tube)
6
Tank
7
Access panel
8
Control opening
9
Built-in check valve
10 Engine-pump assembly
11
Shredding system
The pumping station is equipped with several horizontal and vertical inlet
openings for 40/50/100/110 mm outside diameter piping (1) and 40/50 mm
outside diameter piping (2). The engine-pump assembly (10) carries the
pumped fluid in the vertical discharge piping with an outside diameter of
50 mm (3) and outside diameter of 110 mm for the SANICUBIC® 2 XL. The
ventilation duct (4) allows the tank to always remain at atmospheric pressure.
Operating mode:
Effluents enter the pumping station through the horizontal and vertical inlet
openings (1) (2). They accumulate in a gas-tight, smell-proof and watertight
plastic tank (6). Controlled by a level sensor (5) and a control box, effluents are
shredded by the shredding system (11) or carried away by a vortex impeller
for the SANICUBIC® 2 XL and automatically pumped, when they reach a cer-
tain level in the tank, by one or two pumps, depending on the model, (10)
above the back-flow level to flow into the discharge line.
- SANICUBIC® 1/SANICUBIC 1® WP contains one pump equipped with a high-
performance shredding system.
- SANICUBIC® 2 Classic/SANICUBIC® 2 Pro contains two independent pumps.
Each of these pumps is equipped with a high-performance shredding system.
Both pumps operate each in turn, alternately. In case of abnormal operation,
both engines run simultaneously (or if one pump fails, the other takes over).
- SANICUBIC® 2 XL contains two independent pumps, each with a clearance
of 50 mm. Both pumps operate each in turn, alternately. In case of abnormal
operation, both engines run simultaneously (or if one vortex pump fails, the
other takes over).
Level sensor / Dip tube:
• 2 Long dip tubes
During normal operation, as soon as the effluents reach the long tube's ac-
tuation level in the tank, the pumping system switches on.
• Short dip tube
During abnormal operation, if the effluents reach the highest level in the tank
(short tube), an audible and visual alarm system is activated and the pum-
ping system switches on (if it is not faulty).
21
9
3
4
2
1
7
1
10
11
Ø ext.40/50/100/110 mm
Ø ext. 40/50 mm
Ø ext. 50 mm
Ø ext. 50 mm