GENERAL RECOMMENDATIONS BEFORE STARTING THE INSTALLATION
The performance and accuracy of the system are strongly infl uenced by the position and orientation of the sensors. For this reason
certain conditions have to be checked before starting the installation:
• On the positions chosen to place the sensors the bumper must provide enough depth internally and room for assembly
without any forcing.
• Follow the positioning instructions and the tips on the accessories to be used, depending on the height and shape of the
bumper.
It is extremely important to fi t the sensors on the bumper and keeping a height that can vary from a maximum of about 65 cm to a
minimum of 35 cm. It is important that the sensors are as vertical as possible from the ground.
Fig. 3a
For this reason two types of spacer are part of the optional ESH pack (ABP0214): one has 5° inclination A and one a 10° inclination
B (see installation with ring nut accessories S and T); they are indispensable to realign any incorrect inclination of the sensor, due
to the shape of the bumpers. If, even with both spacers, it is impossible to get a vertical position, then it is preferable to use the one
that allows to reach the highest position. If the bumper allows for a vertical position, the capsule fi xing ring nut can be used without
any spacer and in these conditions it is also possible to use the ISH system (see installation with ISH fi g.5a and fi g.5b).
Fig. 4
The distance between the sensors can vary from a minimum of 30 cm to a maximum of 70 cm. The important thing is that there
must be the same distance between them all, likewise the external distances (as much as possible). If feasible it is advisable to po-
sition them as shown in the fi gure. When evaluating the position of the capsules it is important to consider their range of action:
FRONT
Fig. 3b
SENSORS FIXING POSITIONS
internal: 110 cm approx.
external: 90 cm approx.
SENSORS POSITIONS
14
internal: 150 cm approx.
REAR
external: 100 cm approx.