Malfunctions

Malfunction
Machine without function
Brush does not rotate
Poor suction performance Ground re-
mains wet Soiled water is not
vacuumed up
Suction unit switches off
Insufficient cleaning solution supply
Brush unit or suction unit cannot be
turned off
Machine stop without a malfunction
Possible causes
Machine is switched off
Press emergency stop
Main fuse is defective
Error code on the display
Batteries discharged or battery
charger defective
Batteries defective
Brush drive switched off
Main fuse is defective
Motor rotates, brush does not
Suction not switched on
Suction nozzle / squeegee not on
the floor
Blades worn out
Suction hose or squeegee clogged
(e.g. pieces of wood, pieces of fab-
ric)
Suction filter clogged
Recovery tank full
Recovery tank contaminated
Fresh water tank empty
Quantity of the cleaning solution is
set too low
Fresh water tank filter blocked
Error in the electronic system or in
the control panel
The drive wheels could possibly
have been blocked by an object
Troubleshooting
• Switch the machine on
• Release the emergency stop
• Check/replace fuse
• Contact your service partner
• Contact your service partner
• Load batteries
• Contact your service partner
• Contact your service partner
• Press Brush button
• Replace fuse
• Contact your service partner
• Check if the tool is engaged
• Contact your service partner
• Press suction unit button
• Check suction nozzle / squeegee
suspension for functionality
• Replace blades
• Remove any foreign matter
• Remove any foreign matter
• Drain recovery tank
• Check fuse
• Check recovery tank and clean it,
if necessary
• Check fresh water tank
• Adjust cleaning solution volume
with +/- buttons
• Filter
• Stop the machine using emergen-
cy stop
• Contact your service partner
• Remove the object