The third menu is the one defined as EXTENDED 2 and to access the programmable functions follow the instructions given in Tab. 4:
EXTENDED
• Press the SELECT button and scroll the LED menu until you
MENU 2
reach the LEV LED;
• Press SET twice to access the EXTENDED menu 2.
LIVEL 2 - EXTENDED MENU 2
LED
FUNCTION
L1
BRAKE
Enabling of the electronic brake
L2
STEP BY STEP 1
Step-By-Step logic
L3
ALWAYS CLOSE
Enables the sending of a CLOSE
command when the power is
turned on again
L4
FOLLOW ME
The motor automatically closes in
5 sec after passing through DS1
photocell
L5
PEDESTRIAN TIME
Storage of motor no.1 partial
stroke with slowdowns
L6
2°CH
Setting the aux. relay of the
MONOSTABLE /
2°CH as Bistable / Monostable /
BISTABLE/TIMED
Temporised monostable
MONO.
L7
REMOTELY
Enable the remote control
PROGRAMMING
memory function without acting
on the control unit
Table 4
The fourth and last menu is defined as EXTENDED 3 and to access the programmable functions follow the instructions given in Table 5:
EXTENDED
• Press the SELECT button and scroll the LED menu until you
MENU 3
reach the LEV LED;
• Press SET 3 times to access the EXTENDED menu 3.
LIVEL 3 - EXTENDED MENU 3
LED
FUNCTION
L1
SOFT STOP
Setting of gradual slowdown at
the end of the movement
L2
SOFT START
Setting of gradual slowdown at
the beginning of the movement
L3
RELEASE STROKE
Before opening, the closing thrust
MAX FORCE/
is activated for the electric lock
RELEASE STROKE
release
L4
SLAM LOCK MAX
Activation of the push in closing
FORCE / SLAM
for electric lock release
LOCK
L5
ELS / CMD PED
Activation of the electric lock as
PPED input
L6
LAMP/INDICATOR
Flashing light set as pilot light or
LIGHT/COURTESY
courtesy light
LIGHT/
L7
PRELAMP / LAMP
Activation of the pre-flashing of
IN PAUSE
3 sec. before closing / Flashing
during the pause time
Table 5
Note: The control unit allows to be programmed if all the safety devices (N.C. inputs on terminals) grant a contact closed.
38
COMUNELLO ®Copyright 2021 - All rights reserved
DESCRIPTION
Enabled function
Open-Stop-Close-Stop (It DOESN'T close after the pause time in a
partial opening phase)
Enabled function
Enabled function
Partial stroke of motor no.1 stored
Bistable command
Enabled function
DESCRIPTION
Enabled function
Enabled function
Active function
Active function
Enabled function
The courtesy light / warning light becomes an intermittent output, while
the lamp output becomes a courtesy light"
Active function: preflash in closing / Flash during pause
time
The LED of the LEV function FLASHES with this frequency
LED ON
Disabled function
Disabled function
Disabled function
Disabled function
Monostable command (impulsive)
Disabled function
The LED of the LEV function FLASHES with this frequency:
LED ON
Disabled function
Disabled function
Disabled function
Disabled function
Disabled function
Flashing light
Disabled function
LED OFF
DEFAULT
10 sec., without slowdowns
LED OFF
DEFAULT