• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
8.2.4. LED L4 - PHOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.2.5. LED L5 - DS2 STOP IN CLOSE:
The control unit allows the operation of input DS2 to be modified. If you
want DS2 to trip also during closing (stopping of the gate leaf, then once
the passage is free, the gate resumes the closing manoeuvre) proceed as
follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• Press the SET key;
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.2.6. LED L6 - DS1 PARTIAL INVERSION:
The control unit allows the operation of input DS1 to be modified. If, during
a closing manoeuvre, you want DS1 to perform a partial reversal (short
reversal) of the gate leaf instead of a total reversal, proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• LED L6 becomes steady on and programming will be completed
Repeat the procedure if you wish to restore the previous configuration.
8.2.7. LED L7 - BLOCK / 8K2:
The control unit allows the connection of an N.C. Emergency Stop
pushbutton (CN2 input no. 8). However, to switch this input to an 8.2
KOhm resistive input proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
From this moment on, the connection of a resistive edge to the control unit
in the relative input will result in the colour change (from red to green) of the
STOP / 8K2 led.
A change in the input value causes a partial inversion and the subsequent
block of the control unit in any phase of the leaf stroke.
Repeat the procedure if you wish to restore the previous configuration.
8.3 EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 2,
proceed as follows:
• Select blinking LEV LED and press SET twice;
• Premere 2 volte SET;
• The LED will start blinking (alternate flashing of LED LEV
L1
BRAKE
ON
L2
STEP BY STEP 1
ON
L3
ALWAYS CLOSE
ON
L4
FOLLOW ME
ON
L5
PEDESTRIAN TIME
ON
L6
2°CH MONOSTABLE
ON
L7
DISTANCE PROGRAM.
ON
LEV
MENÙ
This will allow 30 seconds for the selection of Extended Menu 2 functions
using the SEL and SET buttons. After a further 30 seconds, the control unit
returns to the main menu.
8.3.1 LED L1 - BRAKE:
The control unit is factory set with the electronic brake function disabled.
This will allow 30 seconds for the selection of Extended Menu 2 functions
using the SEL and SET buttons. After a further 30 seconds, the control unit
returns to the main menu.
ed as follows:
• Make sure you have enabled the extended Menu 1
(as shown by the alternate flashing 1 1 0 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way the control unit reduces the advancement of the gate due to
inertia, corresponding to a stop or an inversion command.
Repeat the procedure if you wish to restore the previous configuration.
8.3.2 LED L2 - STEP BY STEP 1:
Proceed as follows if you wish to enable the function "Step-by-step 1":
• Make sure you have enabled the extended Menu 2
(as shown by the alternate flashing 1 1 0 1 1 0 1 1 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• Press the SET key;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
Important note: the Step by Step 1 function overwrites the standard Step
by Step logic and can be enabled only if the "Step-by-step" is active and
with a "Pause time" stored.
8.3.3 LED L3 - "ALWAYS CLOSE":
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power failure; if the gate open condition
is confirmed a closing movement is started automatically, preceded by 5
seconds of pre-flashing.
Important note: this function can be programmed only if a Pause Time
has already been set.
If you wish to enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 2
(as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
COMUNELLO ®Copyright 2021 - All rights reserved
);
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2 FLASHES