8.1 MAIN MENU
L1
STEP BY STEP
Step-by-step
L2
CODE TX
Remote control stored
L3
CONDO
ON
L4
MOTOR TIME
Complete stroke stored
L5
PAUSE TIME
With automatic closure
L6
DELAY
ON
L7
PRG AUTOM
ON
LEV
MENÙ
8.1.1 LED L1 - STEP BY STEP or OPEN-CLOSE:
Programming
In the default configuration the control unit is set with "Step-By-Step"
operating logic enabled (LED no.1 ON);
if the "Automatic Open-Close" operating logic is required (LED no.2 OFF),
proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.1;
• Press the SET key;
• The LED L1 turns off and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.2. LED L2 - CODE TX:
CODE TX: Remote controls storage
Up to 120 remotes with different codes of either the fixed or the rolling
code type can be saved on the control unit
Remote control code programming of the total opening (Mot. no. 1 + Mot.
no.2):
• By the key SELECT, position yourself on the blinking LED 2 "CODE TX";
• Press key SET once to memorize the PP channel;
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed;
• The LED L2 starts to blink again to indicate that you have 10 additional
sec. to store a new code;
• On expiry of those 10 sec.the LED L2 will remain steady on.
Remote control code programming of the partial / pedestrian opening
(Mot. no. 1):
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET twice to memorize the PPED channel and the led will
modify its blinking (110110110);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed. The extra time of 10 sec. to store a
new PPED channel is then preview as for the PP channel.
Remote control code programming of the 2nd AUX channel:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET 3 times to memorize the 2nd auxiliary channel and the
led will modify its blinking (1 1 1 0 1 1 1 0);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed.
• The extra time of 10 sec. to store a new AUX channel is then preview as
for the PP channel.
Important note: If a code has already been entered or all 120 codes
have been memorized, by repeating the programming operation, all the
programming LEDs will start to flash, indicating that no further storing is
possible.
Deletion of remote control codes:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Activate the blinking of the code to be deleted (P.P., PED. or AUX,
indicated by the respective blinking);
• Press and hold down key SET for more than 5 sec.;
• The LED switches off for 2 sec. and the procedure is completed;
• If the CODE, PEDESTRIANS, or AUX codes are deleted, the LED will
remain off.
Important note: If both channels codes are deleted, the LED will remain
off, by the contrary if only PEDESTRIAN codes remain stored, the LED
blinking mode will change (1 1 1 1 0 1 1 1 1 0).
Automatic (Open-Close)
No remote control stored
Rule of the first saved Remote control:
When programming remotes the following rule is applied:
OFF
if the first remote to be saved is a rolling code type, the receiver will
30 s. (no slowdowns)
subsequently accept only rolling code remotes (thus providing enhanced
OFF
anti-intrusion security); if the first remote to be saved is a fixed code type,
the receiver will subsequently accept both fixed code remotes and rolling
OFF
code remotes, although only the fixed part of the latter will be controlled
OFF
(thus effectively relinquishing the security of the rolling code system).
ON
8.1.3. LED L3 - CONDO: "Condominium" logic:
The enabling of the Condominium function means that during the opening
movement or during the pause time the control unit will not respond to
commands sent by Pushbuttons or remotes.
In contrast, during the closing movement a command sent by the
Pushbuttons or the remotes will reverse the direction of movement. This
operating mode is invaluable when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows:
• By the key SELECT, position yourself on the blinking LED no.3;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.4. LED L4 - MOTOR TIME: Programming of the motors stroke (max
4 min.):
It is necessary to program the working time of the motors (adjustable up to
a maximum of 4 minutes).
To set a new stroke, programming must be carried out with leaves in closed
position as follows:
• By the key SELECT, position yourself on the blinking LED no.4;
• Press the SET key; · Motor no.1 starts the opening phase;
• At the desired initial deceleration point, press the SET key again, LED L4
will start to flash more slowly and Motor 1 will decelerate;
• When the desired complete opening position is reached, press the SET
button to end the Opening cycle;
• LED L4 will now resume flashing normally and Motor 2 will begin
Opening;
• Repeat the work time programming procedure for Motor 2;
• Once programming of the motor Opening times has been completed,
Motor 2 restarts Closing immediately: repeat the above procedures
for the Closing phase of Motor 2 and subsequently Motor 1.
If deceleration is to be excluded (procedure not encouraged), when
opening, wait until the fully open position is reached and press the
SET button twice. During the closing phase, wait until the position of
complete closure is reached and press the SET button twice.
Important notes:
- If you do not require the control unit to perform the deceleration, during
programming, when the open-close cycle has been completed press the
SET key twice consecutively rather than just once.
- If the control unit is used in the 1 Motor configuration (dip 1 of SW1 OFF),
the programming of the working time of the Motor 2 is not performed
- During programming, instead of the SET key on the control unit you can
use the button on the remote already stored.
8.1.5. LED L5 - PAUSE TIME Automatic closing time programming
The control unit is factory set with automatic closing disabled.
If you wish to enable automatic closing proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.5;
• Press the SET key;
• Wait for a time equivalent to the desired time interval (from 1 sec. up to
4 min.);
• Press the SET key again momentarily and at the same time the automatic
closing time will be saved and LED L5 will remain steady on;
If you wish to restore the initial condition (no automatic closing)
COMUNELLO ®Copyright 2021 - All rights reserved