Electrical Requirements
Stacked Tumbler Electrical Connections
All gas and steam stacked tumblers require a single
service connection to TB1 of the upper unit junction
box only. The serial plate reflects current draw,
breaker/fuse size and conductor amperage required for
the entire machine.
All electric stacked tumblers require separate service
connections for each upper and lower unit. Serial plate
ratings reflect current draw, breaker/fuse size and
conductor amperage required per unit.
52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For CE Marked Models Only
(Manual Timer and OPL Micro Models Only)
IMPORTANT: All manual timer and OPL Micro
operated tumblers are factory equipped with an
emergency stop button located on the front panel.
1
Emergency Stop Button
Figure 16
To operate emergency stop button:
a. Press red emergency stop button to stop all
action.
b. To restart machine, pull red emergency stop
button out and press START pad or button.
NOTE: Activation of the emergency stop button
stops all machine control circuit functions, but
DOES NOT remove all electrical power from
machine.
1
T378I