Loading Door Switch

Non-CE Marked Models
The door switch should be adjusted so the cylinder
stops when door is opened 2 inches (51 mm) plus or
minus 1/4 inch (6 mm). This switch is a normally open
switch and is closed by the hinge cam when the door is
closed. If adjustment is required, refer to Figure 19
and proceed as follows:
1. Close door and start tumbler, slowly open loading
door. Cylinder and heat system should shut off
when door is open 2 inches (51 mm) plus or
minus 1/4 inch (6 mm).
2. Slowly close the loading door. When door is
2 inches from being fully closed, the door switch
actuating bracket (located on the door) should
depress the button and the switch arm with an
audible "click."
3. If the actuating bracket does not operate the
switch at the appropriate door closure, bend the
actuating switch arm in or out to achieve proper
actuation.
CE Marked Models
CE Marked tumblers have a second door switch near
the top of the door (refer to Figure 19). This switch
also should be adjusted so cylinder stops when door is
opened within 0 – 2 inches (0 – 51 mm). This switch is
normally closed and is opened by the hinge cam when
the door is opened. If adjustment is needed, refer to
Figure 19 and proceed as follows:
1. Remove lower switch actuator (Figure 19) so
upper switch "click" can be heard.
70223701

Adjustments

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. Loosen upper door switch screws just enough so
switch can be moved left and right. Move switch
right if door opens too far before switch clicks.
Move switch left if door doesn't open far enough
before switch clicks.
3. Retighten door switch screws and retest. Repeat
step 2 if further adjustment is needed.
4. Reinstall lower switch actuator and retest its
switch.