Electrical Requirements for Electric
Models
Refer to Table 19, Table 20 and Table 21.
NOTE: Minimum wire sizes are obtained from
Canadian Electrical Code Table 2 for 90° C
Conductors and are intended for use as a guideline
only. Electrical connections should be made only by
a qualified electrical contractor in accordance with
all applicable local and national requirements.
For 9 kW 25 Pound Electric Models:
Serial Plate
Voltage
400V/50Hz/3ph
For 12 kW 25 Pound Electric Models Starting with Serial No. 9807017296:
Serial Plate
Voltage
208V/60Hz/1ph
240V/60Hz/1ph
200V/50Hz/1ph
230-240V/50Hz/1ph
200-208V/60Hz/3ph
200V/50Hz/3ph
230-240V/50Hz/3ph
240V/60Hz/3ph
380V/50Hz/3ph
400-415V/50Hz/3ph
460-480V/60Hz/3ph
70223701
Terminal Block
Current
Connections
(Amps)
Required
L1, L2, L3,
and ground
Terminal Block
Current
Connections
(Amps)
Required
L1, L2, Neutral,
and ground
L1, L2, Neutral,
and ground
L1, Neutral,
and ground
L1, Neutral,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
Recommended
Fuse or
Breaker Rating
(Amps)
15.2
20
Recommended
Fuse or
Breaker Rating
(Amps)
64.0
80
56.7
80
63.0
80
57.5
80
36.5
50
36.4
50
33.3
50
32.8
50
19.8
30
18.4
30
16.1
30
Table 19
Electrical Requirements
Recommended
Breaker
Minimum
Poles
Conductor Size
[AWG (mm
3
12 (3.53)
Recommended
Breaker
Minimum
Poles
Conductor Size
[AWG (mm
2
3 (31.17)
2
4 (24.62)
1
4 (24.62)
1
4 (24.62)
3
6 (14.19)
3
6 (14.19)
3
6 (14.19)
3
6 (14.19)
3
10 (5.52)
3
10 (5.52)
3
10 (5.52)
2
)]
2
)]
59