Conversion Instructions
If serial plate voltage is:
120 Volt/60 Hertz/
1 Phase
2W&G
240 Volt/60 Hertz/
3 Phase
3W&G
70223701
Tumbler can be converted to the following voltages:
208-240 Volt/60 Hertz/1 Phase Reversing and Nonreversing Models:
3W&G
1. Prior to connecting service, locate the black/red wire which runs between
terminal block and the motor relay or contactor. Refer to figure below.
208 OR
240 V~
2. Disconnect the black/red lead from L1 of the terminal block and connect to
L2 of the terminal block. For stacked tumbler complete steps 1 and 2 for
upper and lower junction box areas.
3. Sign and date conversion sticker located on back of tumbler.
4. Follow the instructions covered in Connecting Electrical Service section.
200-208 Volt/60 Hertz/3 Phase Reversing and Nonreversing Models:
3W&G
1. Prior to connecting electric service, locate transformer configuration jumper
in junction box area.
2. Remove the 240 Volt jumper and replace it with the 208 Volt jumper located
in the literature packet in cylinder.
3. For stacked tumblers, repeat steps 1 and 2 for each upper and lower unit.
4. Sign and date conversion sticker located on back of tumbler.
5. Follow the instructions covered in Connecting Electrical Service section.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
120 V~ LOCATION
(AS RECEIVED)
L1
120 V~
N
120 V~
L2
TERMINAL BLOCK
Electrical Requirements
208 or 240 V~
LOCATION
(AS CONVERTED)
TO MOTOR RELAY
OR CONTACTOR
BLK/RED
T381I